A practical planning guide for homeowners along the Wasatch Front. These are common thicknesses and published local rules, not a permit, an engineered specification, or a bid.
Use this for a continuous footing or grade beam. For round post holes, switch to Post hole / column and enter diameter, depth and the number of holes.
Treats a solid poured stair as a triangular wedge. Treads equal risers minus one (the top landing is the upper floor). This is a planning volume, not a code check for rise and run.
- Volume
- –
- Cubic yards
- –
- 80 lb bags
- –
- 60 lb bags
- –
- Ready-mix material
- –
- Cost in 80 lb bags
- –
- Cost in 60 lb bags
- –
A 10% waste factor is a typical starting point. Use 10–15% on uneven subgrade, odd shapes, or pump jobs. Ready-mix planning prices along the Wasatch Front often land roughly $160–$210 per cubic yard before delivery or short-load fees — enter the quote you have. Bag counts use QUIKRETE Concrete Mix yields (80 lb ≈ 0.60 cu ft, 60 lb ≈ 0.45 cu ft) and round up to whole bags. Other brands may differ; check the bag.
Get a driveway quote
Share the job with up to 3 concrete contractors who service Salt Lake, Davis, Weber and Utah counties.
Get a concrete quoteA common planning thickness is four inches — sometimes more
QUIKRETE’s training guidance says slabs are generally poured 4 inches or 6 inches thick, and that driveways and other slabs that carry vehicles are usually thicker than walkways. On the Wasatch Front, a private residential driveway that only takes passenger cars is commonly planned at four inches on a compacted base. Where trucks, trailers, or RVs will park, or where the approach is steep, contractors often step that up to five or six inches. Going thinner than four inches is a frequent reason a driveway cracks early in a freeze-thaw climate, but the right number for your lot still comes from your contractor and your city, not from a default in a calculator.
Use the calculator above with 4, 5, or 6 inches and compare yardage. A 20-by-24-foot drive at 4 inches is about 5.93 cubic yards before waste; at 6 inches it is about 8.89 yards before waste. That difference shows up on the ticket.
Public approaches often have their own rules
A driveway on your lot and a driveway approach in the public right-of-way are not always held to the same thickness. Two published examples:
- Salt Lake County’s driveway ordinance says that no driveway, including the sidewalk, shall be less than six inches thick, and that construction over a public street or sidewalk needs a permit and inspection.
- Eagle Mountain’s public-works code requires drive approaches in the public right-of-way to be six inches thick, with six inches of gravel base compacted to 95 percent density.
Those rules apply to the public approach in those jurisdictions, not automatically to every private pad. Other Wasatch Front cities have their own standard drawings. If you are replacing the section that meets the street, ask the city before you pour.
Frost depth is about footings, not the slab
West Jordan’s published design criteria list a frost depth of 30 inches. North Salt Lake publishes a footing frost depth minimum of 30 inches and lists weathering as severe, with a winter design temperature of 8°F. Frost depth tells you how deep footings and post holes need to go so they are not sitting in soil that freezes and thaws. It does not mean a driveway slab should be 30 inches thick. The slab still needs a compacted base, control joints, drainage away from the house, and a mix that can survive winter.
Freeze-thaw matters as much as inches
Thickness will not save a slab that was placed on a poor base or a mix that cannot take freezing water. The American Cement Association explains that air-entrained concrete contains microscopic air pockets that give freezing water a place to expand; the amount of entrained air is usually between 4 and 7 percent of the volume, and may be varied for special conditions. North Salt Lake’s design criteria already call the local weathering condition severe. If you are pouring a driveway that will see snow, melt, and occasional deicing salt, ask your contractor for an air-entrained mix, a broom finish, and joints at a sensible spacing — and read the companion guide on pouring concrete in freezing weather in Utah.
Related tools
Size the pour with the Utah driveway cost calculator or the main concrete calculator, then browse the rest of the cluster and city pages below.
City concrete calculators along the Wasatch Front:
Salt Lake County
Weber County
Utah County
Common questions
How thick should a concrete driveway be in Utah?
For a private residential driveway that only takes cars, four inches is a common planning thickness. Five to six inches is often used where trucks, RVs, or a steep approach add load. Public driveway approaches can be thicker because of city or county rules — Salt Lake County, for example, requires that a driveway in the public right-of-way, including the sidewalk, be at least six inches thick.
Does frost depth decide driveway thickness?
No. Several Wasatch Front cities publish a footing frost depth of 30 inches, including West Jordan and North Salt Lake. That figure is for footings, not for the thickness of a driveway slab. The slab still needs a compacted base, joints, and a mix that can take freeze-thaw.
Do I need a permit?
Work in the public right-of-way — an approach, a public sidewalk, or a curb cut — often needs a permit and inspection. Rules differ by city. Check with your building or engineering department before you demolish or pour in the right-of-way.
How do I turn thickness into cubic yards?
Length in feet × width in feet × (thickness in inches ÷ 12), divided by 27, then add waste (10% is a typical start). The driveway cost calculator and the main concrete calculator will do that math.
Sources
- QUIKRETE mixing and placing training guide (slab thickness): quikrete.com
- Salt Lake County Code of Ordinances, Chapter 14.36 (driveways, six-inch minimum in the public way): library.municode.com
- Eagle Mountain Municipal Code 15.65.070 (drive approaches): codepublishing.com
- West Jordan Building & Safety design criteria (frost depth 30 inches): westjordan.utah.gov
- North Salt Lake design criteria (footing frost depth 30 inches; severe weathering): nslcity.gov
- American Cement Association, Working with Air-Entrained Concrete: cement.org